III WALKWAY PAD
PRODUCT DATA SHEET
1 of 1 www.duro-last.com 800-248-0280
Description:
Roof Trak
®
III is a non-skid, maintenance-free
walkway/protection pad. Roof Trak III is an extruded
pad made from both recycled Duro-Last
®
membrane
and an oriented strand polyester reinforcement.
Duro-Last, Inc. manufactures the Roof Trak III
Walkway Pad to provide protection in heavily traveled
rooftop areas. It also provides added protection
around mechanical equipment and as a separator for
sleepers that support mechanical equipment. Field
and laboratory testing have proven that Roof Trak III
can be used in all seasons and applications.
Roof Trak III utilizes factory-attached, 4-inch wide,
white membrane skirts for attachment to the field
membrane by heat welding (hot-air).
Duro-Last, Inc. manufactures Roof Trak III in the
colors and skirt configurations shown in the table
below.
TABLE 1. ROOF TRAK III AVAILABLE COLORS AND SKIRT
CONFIGURATIONS
Sizes Colors
Attachment
Skirts
30 in. x 60 in.
White, Tan and Gray solid colors.
White with safety-yellow skirts.
2 skirts along
60-in. sides
60 in. x 60 in.
White, Tan and Gray solid colors.
White with safety-yellow skirts.
2 skirts along
60-in. sides
30 in. x 60 in.
White solid color.
White with safety-yellow skirts.
Fully skirted
along all 4 sides
Installation:
1. Roof Trak III attachment skirts shall be heat-
welded (hot-air) to the field membrane using a
1.5-inch wide weld along the entire length of the
skirt.
2. Walkway pads installed directly over field seams
shall have one side unattached to allow for the
inspection of field seams for warranty purposes.
Following inspection, the unattached skirt must
be welded to the roof membrane.
3. A 1-inch gap is required between sections of
walkway pad to allow for proper water drainage.
Figure 1. Roof Trak III Available Sizes
TABLE 2. TYPICAL PHYSICAL PROPERTIES
Property Result (US) Result (metric)
Thickness 0.135 in. 3 mm
Weight 0.79 lb./ft.
2
3.9 kg/m
2
Breaking Strength
(machine direction)
516 lb. 2,296 N
Breaking Strength
(cross machine direction)
489 lb. 2,176 N
Elongation
(machine direction)
50% 50%
Elongation
(cross machine direction)
64% 64%
Tear Strength
(machine direction)
45 lb. 200 N
Tear Strength
(cross machine direction)
71 lb. 316 N
Static Coefficient of
Friction (Dry)
0.95
Static Coefficient of
Friction (Wet)
1.19